top of page
Dot Waves_edited.jpg

MITO METER 2.0 [EURO]

Blakes/EnviroSens •  European Unit Values: nanoTesla [nT] & microWatts [uW/m²] 18-Step LED Display Custom EMF & RF/5G Calibration 
Building Biology Pre/Post Screening Tool • 2-Year Warranty
• Free Worldwide Delivery

 In-Stock 

AUD $299

MitoMeter.png
LFM MODE:
Low Frequency - Magnetic Fields
powerlines-electricity.jpg
LFM_MODE.png
40Hz 
10kHz
Step Two: Check PowerGrid Background Magnetic Levels 

1/ Select "LFM - MODE" on the meter. (Low Frequency Magnetic - MODE) 2/ From the back of the property, holding the meter vertical, walk forward towards the overhead or underground street powerlines and note how many lights you have at the back, middle and front of the property. If you have more than one green light, use LFM-X MODE to monitor the property overnight to see your averge and peak field levels. (Note: Background magnetic fields from the powergrid cannot be mitigated unless you move the powerlines. (100k+) Step Two: Check Power Distribution Board 1/ Measure the back side of the power distribution power board from within the property internal wall standing back one meter (yard) with meter positioned horizontal, facing forward. 2/ Make sure no bed or seating is within this field. Step Three: Check Building Internal Magnetic Fields 1/ Repeat measurement Step Two above if air conditioning unit(s), solar inverter or appliance(s) back onto a wall where people spend time or sleep adjacent to the wall. 2/ Check house pluming, floors, walls, celling and kitchen sink for magnetic fields, and make sure no one spends extended time in these fields. If the sink or pluming has a detectable magnetic field, have it looked at immediately, as this could cause a shock or even death. Step Four: Assessing Radiation Levels Compare the results against Building Biology guidelines and the Bio-Initiative Report. (Links below) (Note: Above instructions apply to all three RD10 versions)

EMF/RF Basics

Capture.JPG
LFE MODE:
Low Frequency - Electric Fields
Electrical cable.jpg
LFM_MODE
40Hz 
50kHz
Step Three: Isolate which circuits cause high electric fields.

1/ Select "LFE - MODE" on the meter. (Low Frequency Electric - MODE) 2/ Check beds and places you sit or stand at for extended periods with all circuits switched off at the power distribution board. (Including master switch) 3/ Repeat the above with circuits switched on, one circuit at a time for best results. The light circuits cause the highest levels in most homes with low ceilings. 4/ Compare the results against Building Biology guidelines and the Bio-Initiative Report. (Links below.) Ideally, no lights should be indicated within one to two meters of beds and expect to see one to two lights around a connected laptop or desktop computer. If you have high electric fields around your contected laptop/computer, it will need to be grounded. 5/ We also recommend checking for DE (Dirty Electricity) which can be present where you detect electric fields. Solar power, split air conditioning units, fluorescent lighting and lighting dimming switches are the main offenders. The RD10[AU] will read higher levels when DE is high. You can use a AM/radio off station to listen for it. (Step outside with radio and then back inside to see if you can hear loud static noise.) The other option to test DE is to use a plug in EMI Line tester or Stetzerizer Microsurge Meter. DE is a separate EMF category, just as light requires different measurement devices. (Note: Above instructions apply to all three RD10 versions)

EMF/RF Basics

Capture.JPG
RF MODE:
High Frequency - Wireless Radiation 
Wireless Access Point Installation_edite
Capture_edited_edited.png
 100MHz 
8-10GHz
Step One: Screen Background Radiation Levels

1/ Turn off all electronic devices and phones in the vicinity 2/ Select "RF MODE" on the detector. 3/ Stand still and measure background radiation levels by performing a figure 8 motion with the meter in the air. standing next to the North, East, South, and West facing walls of your home/workplace, observing the displayed levels. 4/ Hold the detector against your chest and rotate your body to identify the direction from which the radiation is propagating. 5/ Compare results against Building Biology & The Bio-Initiative Report. (See links bottom of page.) RF Sound Mode Utilize the sensitive "RF Sound Signature Mode" to pinpoint local problematic devices. This mode aids in refining the environment after eliminating or shielding the major radiation sources. To activate Sound Signature Mode: Move the MODE switch from RF down and up twice within two seconds (RF – LFE – RF – LFE – RF). Two lights will start blinking. Then move the MODE switch one click down to LFM and back to RF (RF – LFM – RF). (Note: Above instructions apply to all three RD10 versions)

EMF/RF Basics

Capture.JPG

Screen Your Property:  3 Modes / 3 Steps 

Specifications MITO METER 2.0 [EURO]
(2025 Model)

MITO_BLACK_Case-Front-2k-.png

RF Power Range 0.5 to 100,000 uW/m2 (60 to +5 dBm, -/+6 dB) Blakes Custom RF/5G Calibration

Magnetic Field Power Range: 1 nT to 5000 nT with 1nT Resolution.
18 - Step LED Display. Guaranteed Accuracy @50/60Hz for Measuring Powergrid. (With 12 Hour recording)

20,000/Per Second RF Sampling Rate for Fast Wireless/5G Signal Detection - Clear Sound Signature Identification

Ultra-Sensitive Single Axis E-Field & Magnetic Sensors (More Sensitive Than 3-Axis EMF Meters).

Weight 1.7 Ounces or 50 Grams,

69mm X 110mm. Sound alarm. Rechargeable LiPo Battery. CE and RoHS Certified
External Battery Light, 

E-Field Power Range: 1-2 to 1000 v/m. Body Voltage Contact Pad.

(Rear of Device, For Body Potential Readings)

​Up to 48 Hours Run Time (LFM-X Mode) 8 Hours Standard Modes -USB ChargingCustom RF & EMF Firmware 1.2.07(xx)

Records 6 Minute RF/5G Event & Plays Back Average & Highest Peak + Estimate Total Accumulated Peak Radiation Time.

specs

Frequently asked questions

FAQ

FAQ

MRx MODES
Monitoring & Measurement Methods

v5-Aaroina-snapshot.png

The MRx measurement Methods* go over and above the standard RF, LFM and LFE Mode techniques of screening environments. While the MRx Modes do not do away with using the traditional techniques of spot-checking non-native EMFs on the fly, it does add standalone monitoring capabilities that do not require additional devices or software. Using the MRx advanced modes will enable you to sample RF sound signatures, record and sample RF total acumlated peak radation, as well as record and monitor powergrid background levels. All these modes will dramatically simplify monitoring environments. For further information and Instructions, open link below. (*Compatible with ENV RD-10[AU] & Mito Meters Only.) https://www.blakes.com.au/post/mrx-measurement-methods

PC-ANDROID-MAC

 EnvioSens Monitoring Software

RD10_Software_edited.jpg

Advanced Users Only - Optional $30 Envirosens Connect Kit Required The Envirosens software allows users to retrieve a full data log of recorded events. All modes can be used with the software, (RF, LFE & LFM) and can be saved or downloaded as a CSV file for further analysis. GPS mapping is also possible when connected to Android GPS capable devices. See software and Windows driver links below.

EMF/RF Basics

Capture.JPG

Building Biology Guide

BB.JPG

ENV RD-10 [STD/AU]




Instruction Manual 

ENV RD-10_Front_edited.png

MITO METER 2.0




Instruction Manual 

Mito-RD-10_User_Manual_edited.jpg

MRx Advanced Features

mrx.JPG

MacOS  EnviroSoft

Android  EnviroSoft

Windows EnviroSoft

Windows PC Driver

EMF Portal - Studies+

PORTAL.JPG

Bio Initiative Report

BIO2012.JPG

Building Biology Evaluation Guidelines

IBN.JPG
Envirosoft

Blakes Electronic Integrators ©2025  Terms & Conditions

Blakes Electronic Integrators ©2025   

bottom of page